Today's new high efficiency furnaces can save up to 50% in operating costs over a ten-year-old furnace. Many 1990 and earlier model furnaces have Annual Fuel Utilization Efficiency (AFUE) ratings of 65% or less. The minimum AFUE rated furnace that can be sold in the United States today is 80% for the Southeast and Southwest, with 90% being the minimum in the North.

Our current product offering starts at 80% AFUE and goes all the way to a very efficient 98%+ AFUE rating. Depending on your average usage, higher AFUE rated furnaces can significantly reduce your gas bill.

The DOE’s regional breakdown by state is as follows:

  • North – 80% AFUE
  • Southeast – 90% AFUE
  • Southwest - 90% AFUE
DOE Regional SEER Breakdown Map

Let MD Lawson Heating and Cooling Help Pick The Right Furnace For Your Home

We offer many furnaces with variable and multi-speed features that can provide enhanced indoor comfort by slowly ramping up to your thermostat setting rather than simply turning on at full speed. This alleviates the "cold air blow" often associated with single speed furnaces, and dramatically reduces system noise. Call us now at (252) 722-2166.

Gas Furnace Product Offering

GRVM97-R32

High-Efficiency, Modulating, Variable-Speed, ECM Gas Furnace-R32

View Brochure
Model Family: GRVM97-R32
Annual Fuel Utilization Efficiency: Up to 97% AFUE
Energy Star Certified: ENERGY STAR® Certified
Blower Motor: VariableSpeed ECM
Gas Valve: Modulating
Inducer Draft Motor: variable-speed induced draft blower
Fan Heating Operation: Multiple continuous fan speed options
Factory Warranty Parts: 10-Year Parts Limited Warranty
Heat Exchanger Warranty: 20-Year Heat Exchanger Limited Warranty + One-Time Heat Exchanger Replacement Limited Warranty* (Yrs 21-99)
Sound Level: Quiet operation
Manufacturer's Stated Benefits:
  • 10-Year Unit Replacement Limited Warranty (good for as long as you own your home),
  • Integrated communicating ComfortBridge™ Technology
  • Heavy-duty aluminized-steel tubular heat exchanger
  • Stainless-steel secondary heat exchanger
GD9T96-R32

Two-Stage, Multi-Speed, ECM Gas Furnace GD9T96

View Brochure
Model Family: GD9T96-R32
Annual Fuel Utilization Efficiency: Up to 96 AFUE
Energy Star Certified: ENERGY STAR Certified
Blower Motor: Energy-efficient, multi-speed ECM blower motor
Gas Valve: Two-stage gas valve
Inducer Draft Motor: Quiet two-speed induced draft blower
Fan Heating Operation: Low continuous fan speed
Factory Warranty Parts: 10-Year Limited Warranty
Heat Exchanger Warranty: Lifetime Limited warranty
Sound Level: Quiet Operation
Manufacturer's Stated Benefits:
  • Self-diagnostic control board with constant memory fault code history output to a LED
  • All models comply with California 40 ng/J Low NOx emissions standard
  • Convenient left or right connection for gas and electrical service
  • Heavy-gauge steel cabinet with durable finish
GR9S92-R32

Single-Stage, Multi-Speed, ECM Gas Furnace

View Brochure
Model Family: GR9S92-R32
Annual Fuel Utilization Efficiency: Up to 92% AFUE
Energy Star Certified: No
Blower Motor: Multi-speed ECM blower motor
Gas Valve: Single-stage gas valve
Inducer Draft Motor: Quiet single-speed induced draft blower
Fan Heating Operation: Single Stage
Factory Warranty Parts: 10-Year Parts Limited Warranty
Heat Exchanger Warranty: 99YR Heat Exchanger Limited Warranty with registration within 60 days
Sound Level: Quiet Operation
Manufacturer's Stated Benefits:
  • Heavy-duty aluminized-steel tubular heat exchanger
  • Stainless-steel secondary heat exchanger
  • Self-diagnostic control board
  • AHRI Certified; ETL Listed
  • Heavy-gauge steel cabinet with durable finish
GR9S80-R32

Single-Stage, Multi-Speed ECM, Multi-Position Gas Furnace

View Brochure
Model Family: GR9S80-R32
Annual Fuel Utilization Efficiency: 80% AFUE
Energy Star Certified: No
Blower Motor: Multi-speed ECM blower motor
Gas Valve: Single-stage gas valve
Inducer Draft Motor: Quiet, single-speed draft induced
Fan Heating Operation: Single Stage
Factory Warranty Parts: 10-Year Parts Limited Warranty
Heat Exchanger Warranty: Lifetime Heat Exchanger Limited Warranty
Sound Level: Quiet Operation
Manufacturer's Stated Benefits:
  • Heavy-duty aluminized-steel dualdiameter tubular heat exchanger
  • Self-diagnostic control board
  • AHRI Certified; ETL Listed
  • Heavy-gauge steel cabinet with durable baked-enamel finish

Daikin Gas Furnaces

DR97MC-R32

Daikin brand DR97MC Variable-Speed blower motor and communicating furnace-R32

View Brochure
Model Family: DR97MC-R32
Annual Fuel Utilization Efficiency: Up to 98% AFUE
Energy Star Certified: ENERGY STAR®
Blower Motor: Variable-Speed ECM Motor
Gas Valve: Self-calibrating modulating gas valve auto-configures for each installation
Inducer Draft Motor: Quiet variable-speed induced draft blower
Fan Heating Operation: Multiple continuous fan speed options offer quiet air circulation
Factory Warranty Parts: 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation.
Heat Exchanger Warranty: 99-Year Heat Exchanger Limited Warranty, online registration must be completed within 60 days of installation.
Sound Level: Quiet Operation
Manufacturer's Stated Benefits:
  • 12-Year Unit Replacement Limited Warranty, online registration must be completed within 60 days of installation.
  • Heavy-duty stainless-steel tubular heat exchanger
  • Stainless-steel secondary heat exchanger
  • Self-diagnostic control board with constant memory fault code history output to a dual 7-segment display
  • Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier
  • Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand
  • Auto-Comfort and enhanced dehumidification modes available
DD96TC-R32

Daikin brand DD96TC Variable-Speed blower motor and communicating systems furnace

View Brochure
Model Family: DD96TC-R32
Annual Fuel Utilization Efficiency: Up to 96% AFUE
Energy Star Certified: No
Blower Motor: Variable-Speed ECM
Gas Valve: Two-stage gas valve provides quiet, economical heating
Inducer Draft Motor: Quiet two-speed induced draft blower
Fan Heating Operation: Multiple continuous fan speed options offer quiet air circulation
Factory Warranty Parts: 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation.
Heat Exchanger Warranty: 99-Year Heat Exchanger Limited Warranty, online registration must be completed within 60 days of installation.
Sound Level: Quiet Operation
Manufacturer's Stated Benefits:
  • 12-Year Unit Replacement Limited Warranty, online registration must be completed within 60 days of installation.
  • Heavy-duty stainless-steel tubular heat exchanger
  • Stainless-steel secondary heat exchanger
  • Self-diagnostic control board with constant memory fault code history output to a dual 7-segment display
  • Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier
  • Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand
  • AHRI Certified; ETL Listed
DR92SN-R32

Daikin brand DR92SN 9-Speed ECM, Multi-Position Gas Furnace

View Brochure
Model Family: DR92SN-R32
Annual Fuel Utilization Efficiency: Up to 92% AFUE
Energy Star Certified: No
Blower Motor: Energy-efficient multi-speed (9-Speed tap) ECM blower motor
Gas Valve: Single-stage gas valve
Inducer Draft Motor: Quiet single-speed induced draft blower
Fan Heating Operation: Multiple continuous fan speed options offer quiet air circulation
Factory Warranty Parts: 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation.
Heat Exchanger Warranty: 99-Year Heat Exchanger Limited Warranty, online registration must be completed within 60 days of installation.
Sound Level: Quiet Operation
Manufacturer's Stated Benefits:
  • 12-Year Unit Replacement Limited Warranty, online registration must be completed within 60 days of installation.
  • Heavy-duty stainless-steel tubular heat exchanger
  • Stainless-steel secondary heat exchanger
  • Self-diagnostic control board with constant memory fault history output to a 3-digit 7 segment LED display and push buttons
  • AHRI Certified; ETL Listed
DR80TC-R32

DR80TC Variable-Speed blower motor Multi-Position gas Furnace R-32

View Brochure
Model Family: DR80TC-R32
Annual Fuel Utilization Efficiency: Up to 80% AFUE
Energy Star Certified: No
Blower Motor: 9 Speed ECM Motor
Gas Valve: Two-stage gas valve provides quiet-economical heating
Inducer Draft Motor: Quiet two-speed draft inducer
Fan Heating Operation: Multiple continuous fan speed options offer quiet air circulation
Factory Warranty Parts: 12-Year Parts Limited Warranty, 12-Year Unit Replacement Limited Warranty, and 99-Year Heat Exchanger Limited Warranty, online registration must be completed within 60 days of installation.12-Year Parts Limited Warranty
Heat Exchanger Warranty: 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation.
Sound Level: 99-Year Heat Exchanger Limited Warranty, online registration must be completed within 60 days of installation.
Manufacturer's Stated Benefits:
  • 12-Year Unit Replacement Limited Warranty, online registration must be completed within 60 days of installation.
  • Heavy-duty stainless-steel dual-diameter-tubular heat exchanger
  • Self-diagnostic control board with constant memory fault code history output to a dual 7-segment display
  • Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand
  • Auto-Comfort and enhanced dehumidification modes available
  • Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier
  • AHRI Certified; ETL Listed